Honeywell Chemicals

Our range of products include hydranal coulomat ag honeywell, honeywell hydranal coulomat ag, hydranal composite 5k 1ltr, hydranal ketosolver honeywell, hydranal coulomat cg honeywell and hydranal coulomat cg-k.

Hydranal Coulomat Ag Honeywell

Request Callback

₹ 12500 / Bottle Get Latest Price

Product Brochure
Packaging Size500 ml
GradeLaboratory Reagent Grade (LR)
BrandHoneywell
Technique SuitabilityCoulometric Titration
Physical FormLiquid
ApplicationLaboratory
Packaging TypeGlass Bottle
Packaging DetailsBottle of 1 Litre
Appearance (colour)Light Yellow
Factor5 mg/ml
Usage/ApplicationLaboratory
Density0.930 g/cm3
Boiling Point (BP)63 DegreeC (1.013 hPa)
Solution TypeSingle Solution
Shelf Life5 Years
Model Name/Number34836

Minimum order quantity: 1 Bottle

  • Hydranal Coulomat AG is a methanol-based anolyte solution used in coulometric Karl Fischer (KF) titration for water content determination. It's designed for use in cells with or without a diaphragm and is known for its quality and reliability in the Hydranal brand. Here's a more detailed description:
    • Function:Coulometric KF titration relies on the reaction of iodine with water, which is generated electrochemically in the titration cell. Hydranal Coulomat AG serves as the anolyte, the solution in the anode compartment of the cell, containing the necessary reagents for this reaction. 
    • Composition:It's primarily composed of methanol, imidazole, sulfur dioxide, and diethanolamine. 
    • Suitability:It's suitable for use in cells with or without a diaphragm, making it versatile for various sample types and titration setups. 
    • Key Properties:
      • pH: 5.0-6.0, which is optimal for accurate water determination. 
      • Density: 0.930 g/cm³ at 20°C. 
      • Boiling Point: 63°C. 
      • Flashpoint: 14°C. 
    • Safety:It's a flammable liquid and classified as a hazardous substance due to its toxicity and potential to cause serious eye damage. Appropriate safety precautions, including wearing protective gear and working in a well-ventilated area, are essential. 
    • Storage:It should be stored at ambient temperature. 
    • Brand:Hydranal is a well-known brand for Karl Fischer titration reagents, recognized for its quality, consistency, and comprehensive product range. 

Honeywell Hydranal Coulomat AG

Request Callback

₹ 13364 / Kg Get Latest Price

Product Brochure
GradeAR/LR/Extra pure/For Synthesis/HPLC Grade/ACS Grade/Technical Grade/IP Grade/BP Grade/USP Grade
BrandHoneywell
Physical FormLiquid
Physical StateLiquid/Powder/Solid/Crystal/Solution/Gas
ApplicationLaboratory
Usage / ApplicationLaboratoryAnalytical/Research/Industrial Use/Synthesis/Microbiology/Education/Food & Beverage/Pharma
Packaging TypePlastic Bottle/Glass Bottle/HDPE Drum/Bag/Can/Ampule
Country of OriginIndia

Minimum order quantity: 1 Kg

Honeywell 34836 is HYDRANAL Coulomat AG, a methanol-based anolyte reagent for coulometric Karl Fischer (KF) titration, used for precise moisture determination in various samples like oils, solvents, and pharmaceuticals, especially for low water content, working in both diaphragm and diaphragm-free cells. It's known for high accuracy, stability, and long shelf life, supporting trace water analysis in industrial and lab settings. Key Characteristics:
  • Product Name: HYDRANAL Coulomat AG
  • Type: Anolyte solution for Coulometric Karl Fischer Titration.
  • Composition: Contains methanol, xylene, and chloroform, making it suitable for non-polar samples and oils.
  • Application: Accurate determination of trace moisture content (water content) in diverse materials.
  • Compatibility: Works with both diaphragm and diaphragm-free coulometric cells.
  • Benefits: High accuracy in the trace range, easy to use, stable cell conditions, and long shelf life.
  • Industries: Used in oil & gas, pharmaceuticals, dairy, and general lab settings. 
In essence, if you're looking for 34836 Honeywell, you're looking for a specific, high-quality chemical reagent for precise water analysis. 

Hydranal Composite 5K 1ltr

Request Callback

₹ 19513 / Litre Get Latest Price

Product Brochure
Packaging Size1 L
BrandHoneywell Fluka
Packaging DetailsGlass Bottle
Physical FormLiquid
ApplicationLaboratory
Packaging TypeGlass Bottle
Usage/ApplicationLaboratory/Pharmaceuticals or R&D
ColorBrown
Country of OriginMade in India
GradeVolumetric One-Component KF Titration
Product Code34816
Density1.170 g
Flashpoint99 C
FormLiquid
Incompatible MaterialsStrong Oxidizing Agents
Storage TemperatureAmbient
Pack Size1L
SuitabilityTest Passed

Minimum order quantity: 1 Litre

Hydranal Composite 5 K is a titrating agent used in volumetric one-component Karl Fischer (KF) titration, specifically for aldehydes and ketones. It's a methanol-free reagent, meaning it doesn't contain methanol, which is often a component in other KF reagents. This makes it a safer and more environmentally friendly option. It's a liquid solution, and its titer (water equivalent) typically ranges from 4.5 to 5.5 mg/mL. Here's a more detailed breakdown:
  • Purpose: Hydranal Composite 5 K is designed for determining the water content of various substances using the Karl Fischer titration method. 
  • Methanol-free: This is a key feature, making it a safer and more environmentally conscious alternative to reagents that contain methanol. 
  • Composition: It contains iodine, sulfur dioxide, and bases like imidazole and 2-methylimidazole, dissolved in diethylene glycol monoethyl ether (DEGEE). 
  • Stability: The inclusion of 2-methylimidazole enhances the reagent's stability and helps prevent the formation of crystals, which can interfere with the titration process. 
  • Suitability: It is specifically suitable for KF titration in aldehydes and ketones. 
  • Titer: The titer, which indicates the reagent's strength or water equivalent, is typically in the range of 4.5-5.5 mg/mL. 
  • Color: The reagent is typically brown. 
  • Density: Its density is around 1.170 g/cm³ at 20°C. 
  • Flashpoint: The flashpoint is approximately 99°C. 
  • Incompatible materials: It is incompatible with strong oxidizing agents. 
  • Packaging: It is available in various sizes, including 1L and 2.5L bottles, to suit different laboratory needs. 

Hydranal Ketosolver Honeywell

Request Callback

₹ 14694 / Litre Get Latest Price

Product Brochure
Packaging Size1 L
Packaging DetailsGlass Bottle
Usage/ApplicationLaboratory
BrandHoneyWell Fluka
ColorColorless
Country of OriginMade in India
Product Code34738
Boiling Point85 C
Density0.910 g
FormLiquid
Product LineHydranal
Storage TemperatureAmbient
Incompatible MaterialsStrong oxidizing agents, Alkali metals, Ammonia, Peroxides

Minimum order quantity: 1 Litre

HYDRANAL™ - KetoSolver is a methanol-free, one-component reagent used for volumetric Karl Fischer titration in aldehydes and ketones. It is a colorless liquid with a density of 0.910 g/cm3 at 20°C. The reagent is designed for applications where methanol is incompatible with the sample, such as in the analysis of organic compounds like aldehydes and ketones. Here's a more detailed description: 
  • Purpose:Used for determining water content in samples that contain compounds that react with methanol, like aldehydes and ketones.
  • Key Features:
    • Methanol-free: Suitable for a wide range of organic samples.
    • One-component: Simplifies the titration process, making it more convenient and less prone to errors.
    • Versatile: Can be used in various applications, including research and industrial analysis.
  • Chemical Properties:
    • Synonym: Methylidyne Trichloride or Trichloromethane.
    • Boiling point: 85 °C (1.013 hPa).
    • Color: Colorless.
    • Density: 0.910 g/cm3 (20 °C).
    • Flashpoint: 21 °C.
    • Form: Liquid.
  • Incompatibility:Not suitable for use with strong oxidizing agents, alkali metals, ammonia, or peroxides.
  • Availability:Available for purchase from scientific supply companies like Honeywell Research Chemicals.
  • +++++

Hydranal Coulomat CG Honeywell

Request Callback

₹ 14500 / Bottle Get Latest Price

Product Brochure
Formulation TypeLiquid catholyte reagent.
Packaging Size50ML
Purity99 %
BrandHoneywell
Packaging DetailsBox
Usage/ApplicationLaboratory
ColorLight Yellow
Country of OriginMade in India
GradeCoulometric KF Reagents
FormLiquid
Product Code34840

Minimum order quantity: 1 Bottle

HYDRANAL Coulomat CG is a methanol-based catholyte solution used in coulometric Karl Fischer titration, a method for determining water content in samples. It's a trusted brand known for quality and consistency, with a wide range of products and support resources available. Key aspects of HYDRANAL Coulomat CG:
  • Purpose:Used as a catholyte in coulometric Karl Fischer titrations to measure water content.
  • Composition:Methanol-based.
  • Features:
    • Pyridine-free and ethanol-based.
    • Known for quality, consistency, and innovation.
    • Part of a comprehensive Hydranal product portfolio.
    • Offers dedicated technical support and numerous application notes.
  • Safety:Harmful, flammable, and poses health hazards. Requires protective gear and careful handling.
  • Properties:
    • Color: Light yellow.
    • Density: 1.064 g/cm3 at 20°C.
    • Flash point: 14°C.
    • Incompatible with oxidizing agents. 

HYDRANAL Coulomat CG-K

Request Callback

₹ 26217 / Piece Get Latest Price

Product Brochure
Packaging Size5ML
BrandHoneywell
Packaging DetailsGlass Bottle
ApplicationLaboratory
Packaging TypePlastic Bottle
Usage/ApplicationLaboratory
ColorLight Yellow
Country of OriginMade in India
GradeCoulometric KF Reagents
Product Code34821
Pack Size50ML
FormLiquid

Minimum order quantity: 1 Piece

HYDRANAL - Coulomat is a range of reagents used for coulometric Karl Fischer titration, a method for determining water content in various materials. These reagents are specifically designed for coulometric KF titration and come in different formulations, including anolytes (like HYDRANAL - Coulomat AG) and catholytes (like HYDRANAL - Coulomat CG). They are known for their quality, consistency, and innovation in the field of Karl Fischer titration. Here's a more detailed breakdown:
  • HYDRANAL - Coulomat AG:This is a methanol-based anolyte, meaning it's used in the anodic compartment of the coulometric titration cell. It has a pH of 5.0-6.0, making it suitable for accurately determining water content in various samples. 
  • HYDRANAL - Coulomat CG:This is a methanol-based catholyte, used in the cathodic compartment of the titration cell. 
  • Other Hydranal Coulomat Reagents:The HYDRANAL - Coulomat series includes various formulations for different applications, such as HYDRANAL - Coulomat A (methanol-chloroform based anolyte) and HYDRANAL - Coulomat E (ethanol-based catholyte). There are also variations like HYDRANAL - Coulomat Oil (for oils and non-polar samples) and HYDRANAL - Coulomat AK (methanol-free, for suppressing side reactions in ketone titration). 
  • Coulometric KF Titration:This technique involves using a controlled electric current to react with water in the sample and determine its quantity. 
  • Importance of Quality:HYDRANAL reagents are known for their high quality, which is crucial for accurate and reliable water determination in Karl Fischer titration. 

Honeywell Hydranal Coulomat AG

Request Callback

₹ 13364 / Bottle Get Latest Price

Product Brochure
Packaging Size500 ml
GradeAR Grade
Packaging DetailsBottle of 500 ml
Density0.930 g/cm3 (20 DegreeC)
BrandHoneywell
Usage/ApplicationLaboratory
Boiling Point (BP)63 DegreeC (1.013 hPa)
ColorLight Yellow
FormLiquid
Flashpoint14 DegreeC
SynonymsKarl Fischer reagent
Brand NameFluka

Minimum order quantity: 1 Bottle

Honeywell HYDRANAL™ Coulomat AG is a methanol-based anolyte solution used in coulometric Karl Fischer titration for determining water content. It's designed for use in titration cells, both with and without diaphragms. This reagent is known for its quality, consistency, and reliability in water determination, and is part of Honeywell's comprehensive HYDRANAL product line. Key features and properties:
  • Application: Coulometric Karl Fischer titration for water content analysis.
  • Composition: Methanol-based solution.
  • Cell Compatibility: Suitable for both cells with and without diaphragms.
  • pH: 5.0-6.0, ideal for accurate water determination.
  • Density: 0.930 g/cm³ at 20°C.
  • Boiling Point: 63°C.
  • Shelf Life: 5 years.
  • Packaging: Available in various glass bottle sizes.
  • Brand: Part of the HYDRANAL™ line, known for quality and consistency in Karl Fischer reagents. 

Honeywell Hydrochloric Acid

Request Callback

₹ 16500 / Piece Get Latest Price

Product Brochure
Packaging TypePlastic Bottle
Physical FormLiquid
BrandHoneyWell
Packaging DetailsPlastic Bottle
Cas Number7647-01-0
Packaging Size1 L
Chemical FormulaHCl
Purity99%
Usage/ApplicationLaboratory/Pharmaceutical or R&D
ColorWhite
AppearanceColorless
Country of OriginMade in India
FormLiquid

Minimum order quantity: 1 Piece

Honeywell offers various grades of hydrochloric acid (HCl) for laboratory and industrial applications. Hydrochloric acid, also known as muriatic acid, is a corrosive, strongly acidic solution of hydrogen chloride in water, with a strong, pungent odor. It's a colorless, corrosive liquid, and is completely miscible with water. Honeywell's offerings include reagent grade and semiconductor grade HCl, with different specifications like purity, residue on ignition, and other impurities. Key Properties and Specifications:
  • Chemical Formula: HCl
  • Appearance: Colorless liquid with a pungent odor
  • Corrosivity: Corrosive to metals
  • Solubility: Completely miscible with water
  • Grades: Reagent grade, semiconductor grade, and others
  • Purity: Varies by grade, for example, reagent grade can be 99.999% pure, according to Honeywell
  • Boiling Point: Approximately 42°C (1.013 hPa)
  • Density: 1.190 g/cm³ (20°C)
  • pH: >0.1 (20°C)
  • Molar Mass: 36.46 g/mol
  • Vapor Pressure: 190 hPa (20°C) 
Honeywell's Offerings:
  • Fluka Premium Grade: Available for worldwide distribution, according to Honeywell
  • Semiconductor Grade: Puranal™ products, including VLSI and SLSI grades
  • Reagent Grade: Suitable for analytical and chemical laboratories
  • Solutions for Volumetric Titration: Honeywell offers solutions for volumetric titration, including acids, bases, and salts
  • TraceSELECT: For inorganic trace analysis 
Industrial and Laboratory Uses:
  • Steel Pickling: Removing rust or iron oxide scale before further processing
  • Chemical Synthesis: Used in the manufacture of plastics and other chemical reactions
  • Water Treatment: pH adjustment and regeneration of ion-exchange resins
  • Laboratory Applications: Titration, analytical chemistry, and general reagent
  • Household Cleaning: Concrete, masonry, and toilet bowl cleaning
  • Textile and Leather Industries: Bleaching and processing 

Hydranal Ketosolver Honeywell

Request Callback

₹ 18500 / Bottle Get Latest Price

Product Brochure
Packaging Size1 L
BrandHoneyWell
Packaging DetailsGlass Bottle
Technique SuitabilityVolumetric Titration
Usage/ApplicationLaboratory/R&D
ColorColorless
Country of OriginMade in India
GradeVolumetric One-Component KF Titration
Product Code34738
Boiling Point85 C
Density0.910 G
Flashpoint21 DegreeC
Storage TemperatureAmbient
Pack Size1L

Minimum order quantity: 1 Bottle

HYDRANAL KetoSolver is a methanol-free, liquid medium used for volumetric one-component Karl Fischer titration in aldehydes and ketones. It is specifically designed to dissolve and react with the water content in these types of samples. The reagent is known for its ease of use and accuracy in determining the water content. Key Features and Properties:
  • One-component system:It simplifies the titration process compared to two-component systems. 
  • Methanol-free:This eliminates the need for a methanol-specific reaction, which can cause interference. 
  • Suitable for aldehydes and ketones:The medium is specifically designed for use with these types of organic compounds. 
  • Volumetric:The titration is performed by measuring the volume of reagent needed to react with the water in the sample. 
How it Works:HYDRANAL KetoSolver contains specific components, including imidazole or 2-methylimidazole, which react with water in the sample. The titration process involves adding the reagent to the sample until the reaction with water is complete, as indicated by a color change or electrical endpoint. Safety Information:
  • Flammable:The solvent is flammable, so it should be handled with caution, keeping it away from heat, sparks, and open flames.
  • Irritant:The reagent can cause skin and eye irritation, so proper safety precautions, such as wearing gloves and eye protection, should be taken when handling it. 

Hydranal Coulomat AG-H

Request Callback

₹ 18000 / Bottle Get Latest Price

Product Brochure
Formulation TypePyridine Free
GradeAR Grade
BrandHoneywell
Packaging DetailsGlass Bottle
Usage/ApplicationLaboratory
ColorLight yellow
Country of OriginMade in India
CAS number67-56-1
Density~0.930 g/cm³ at 20 °C
Pack Size500ml
Boiling point/boiling range63 °C at 1.013 hPa
Flash point~14 °C
pH(20 °C): ~5.0-7.0
Formliquid
Odouraromatic
Water solubilitycompletely miscible

Minimum order quantity: 1 Bottle

Hydranal Coulomat AG-H Anolyte for coulometric Karl Fischer titration in long-chained hydrocarbons (methanol-pentanol-based), preferred for cells with diaphragm Suitability: use tested, for cells with and without diaphragm, Reagent for coulometric KF titration in long-chained hydrocarbons (anolyte solution).
Honeywell's HYDRANAL Coulomat AG is a methanol-based anolyte solution for coulometric Karl Fischer titration used to determine water content in samples. It is a reliable, high-accuracy reagent designed for use in both cells with and without diaphragms. Key features include a long shelf life, and it is available in various sizes and packaging, such as 500 ml, 1 L, and 2.5 L glass bottles.

HYDRANAL Water Standard 0.1 Honeywell

Request Callback

₹ 9151 / Piece Get Latest Price

Product Brochure
Packaging Size40ML
GradeExtra Pure
BrandHoneywell
ColorWhite
Boiling Point/Rangea)143-145 °C (1.013 hP
Density0.88 g/cm3 (20 °C)
Flashpoint7.6 %(V)
FormLiquid
Incompatible MaterialsStrong oxidizing agents, Formation of explosive gas/air mixtures
Lower Explosion Limit1.7 %(V)
Melting Point/Ranget 3.13 (25 °C)-25 °C
Partition Coefficien3.13 (25 °C)
Solubility in WaterInsoluble
Upper Explosion Limit7.6 %(V)
Vapor Pressure0.67 hPa (20 °C)
Product LineHydranal™
Storage Temperature2-8 °C
Product Code34847

Minimum order quantity: 1 Piece

HYDRANAL-Water Standard 0.1 is a liquid standard used for calibrating Karl Fischer titrators, with a precisely known water content of 0.10.10.1 mg/g or 0.01%0.01 %0.01%. It is a solvent-based solution with a high-purity, oil-like base and is verified against national standards like NIST SRM 2890. The standard is packaged in individual, easy-to-open ampoules under an argon atmosphere and is used to ensure accuracy and precision in water content analysis. Key features 
  • Purpose: Calibrating and validating Karl Fischer titrators for accurate water content measurement.
  • Water content: 0.10.10.1 mg of H2Ocap H sub 2 cap O��2�� per gram of solution (0.01%0.01 %0.01%).
  • Base: A solvent mixture, often with a xylene-based solvent, which has a specific gravity of approximately 0.860.860.86 g/mL.
  • Calibration: Verified against national metrological standards, such as NIST SRM 2890. 
  • Packaging: Sold in boxes containing multiple 4mL glass ampoules that are sealed under an argon atmosphere.
  • Shelf life: Long shelf life, typically up to five years. Safety information
    • Flammable: Classified as a flammable liquid.
    • Irritant: Can cause skin, eye, and respiratory irritation.
    • Health hazards: Harmful in contact with skin and harmful if inhaled or swallowed and entering the airways. 
    • HYDRANAL Water Standards are liquid solutions with precisely known water content, used for calibrating and validating Karl Fischer titrators. They are packaged in easy-to-open ampoules and tested against NIST reference materials. These standards are used for titer determination, ensuring accuracy and precision in water content analysis. Key Features of HYDRANAL Water Standards:
      • Purpose: Calibrating and validating Karl Fischer titrators, ensuring accuracy and precision in water content analysis. 
      • Form: Liquid solutions with a specific water content. 
      • Packaging: Individual ampoules (often 10 per pack) for single use, under an argon atmosphere. 
      • Testing and Calibration: Tested against national metrological standards (e.g., NIST SRM 2890) and calibrated based on high-purity water or traceable to SI units. 
      • Shelf Life: Long shelf life, often up to five years. 
      • Applications: Titer determination, monitoring precision and accuracy, validation and inspection of Karl Fischer titrators, and volumetric/coulometric Karl Fischer applications. 
      • Versatility: Available in various water content levels (e.g., 0.1 mg/g, 1 mg/g, 10 mg/g). 
      • Example: Honeywell Research Chemicals offers a 0.1 mg/g standard. 

Ethyl Acetate LCMS Honeywell

Request Callback

₹ 7450 / Litre Get Latest Price

Product Brochure
Packaging Size2.5 L
GradeLR (Laboratory)
BrandHoneywell
Physical StateLiquid
Usage / ApplicationLaboratory
Packaging TypeGlass Bottle
Purity>99%
Country of OriginIndia
CAS Numbe141-78-6
Solvent: Used in adhesives, paints, coatings, varnishes, lacquers, and nail polish
AppearanceColorless liquid
Formula\(C_{4}H_{8}O_{2}\)
OdorSweet, fruity
Boiling point\(77.1^{\circ }C\)
vapor density3 (20 °C, vs air)
Product Code34972

Minimum order quantity: 1 Litre

Ethyl acetate (C4H8O2cap C sub 4 cap H sub 8 cap O sub 2��4��8��2) is an organic ester with a colorless, volatile liquid form and a sweet, fruity odor. It is produced from the reaction of ethanol and acetic acid and is widely used as a solvent in products like nail polish, paint, and glues. While it has aProperties 
  • Appearance: Colorless liquid
  • Odor: Sweet, fruity
  • Formula: C4H8O2cap C sub 4 cap H sub 8 cap O sub 2��4��8��2
  • Boiling point: 77.1∘C77.1 raised to the composed with power cap C77.1∘�� 
  • Flash point: 11∘C11 raised to the composed with power cap C11∘��
  • Flammability: Highly flammable
  • Solubility: Soluble in water and most organic solvents 
 relatively low toxicity, it is highly flammable and can cause irritation upon overexposure. 

Honeywell Hydranal Coulomat AG

Request Callback

₹ 15000 / Bottle Get Latest Price

Product Brochure
Formulation TypeVolumetric Karl Fischer Reagent
Packaging Size1 L
Purity99 %
BrandHoneywell
Packaging DetailsGlass Bottle
Chemical FormulaNo
Physical FormLiquid
Cas Number68007-08-9
ApplicationLaboratory
Packaging TypeGlass Bottle
Usage/ApplicationLaboratory
ColorLight Yellow
Country of OriginMade in India
Density0.930 g/cm3 (20 DegreeC)
Pack Size1L
Boiling Point/Range63 DegreeC (1.013 hPa)
Flashpoint14 DegreeC
FormLiquid
pH-Value5.0-6.0 (20 DegreeC)
Storage TemperatureAmbient
Solubility in WaterCompletely miscible

Minimum order quantity: 1 Bottle

Hydranal Coulomat AG is a methanol-based anolyte solution used in coulometric Karl Fischer (KF) titration for determining water content. It's a key component in the titration process, specifically for the anode compartment of the titration cell. The reagent is known for its quality and reliability within the Hydranal brand, and is designed for use in cells with or without a diaphragm. Key Features and Properties:
  • Composition:Primarily composed of methanol, imidazole, sulfur dioxide, and diethanolamine. 
  • Function:Acts as the anolyte in coulometric KF titrations, providing the necessary reagents for the electrochemical generation of iodine, which reacts with water. 
  • Suitability:Can be used in both cells with and without diaphragms, making it versatile for different sample types and titration setups. 
  • Quality and Reliability:Hydranal Coulomat AG is part of a comprehensive portfolio of KF reagents from Honeywell Research Chemicals, known for its quality and consistency. 
  • Safety:Flammable liquid, classified as a hazardous substance due to toxicity and potential for serious eye damage. Requires careful handling and proper safety precautions. 
Specific Applications:
  • Coulometric KF Titration: Used in the determination of water content in various samples through the coulometric KF method. 
  • Anolyte in Titration Cells: Specifically designed for the anode compartment of the titration cell. 
  • Cells with or without a Diaphragm: Suitable for use in both types of cells, offering flexibility in titration setups. 

Acetic Acid Honeywell

Request Callback

₹ 15000 / Piece Get Latest Price

Product Brochure
Packaging Size50ml
GradeLab Grade
BrandHoneywell
Packaging DetailsGlass Bottle
Physical FormLiquid
Usage/ApplicationPharmaceuticals
ApplicationLiquid
Packaging TypePlastic Bottle
Purity99%
Physical StateLiquid
Country of OriginMade in India
ColorColorless
Density1.05 g/cm3 (20 DegreeC)
Melting Point16 DegreeC
Storage TemperatureAmbient
Linear FormulaCH3CO2H
CAS Numbers64-19-7
pH-ValueAcidic
Partition Coefficient-0.17
Product Code49199
FormLiquid

Minimum order quantity: 1 Piece

 Acetic acid from Honeywell is a clear, colorless organic liquid with the chemical formula CH3COOH, also known as ethanoic acid. It is a lab-grade chemical with a purity of 99% and is used in various applications, including pharmaceuticals, Indian website. Honeywell's version is often available as a reagent grade for chemical synthesis and other industrial uses, as well as in semiconductor applications. Key Features and Properties:
  • Chemical Formula: CH3COOH
  • Purity: 99%
  • Grade: Lab Grade
  • Appearance: Clear, colorless liquid
  • Density: 1.05 g/cm3 at 20°C
  • Melting Point: 16°C
  • pH Value: Acidic
  • CAS Number: 64-19-7
  • Uses: Pharmaceuticals, lab reagents, chemical synthesis, semiconductor manufacturing. 
Applications:
  • Semiconductor Industry: Used in etching processes due to its lower dielectric constant compared to water, leading to higher oxidation power. 
  • Analytical Chemistry: Used as a solvent and reagent in various analytical techniques. 
  • Pharmaceuticals: Used in the production of various pharmaceutical compounds. 
  • Industrial Applications: Used in the production of vinyl acetate monomer (VAM), ester production, and other industrial processes. 
  • Other Uses: It is a component of vinegar and is used in the production of cellulose acetate for photographic film, polyvinyl acetate for wood glue, and synthetic fibers and fabrics. 

Hydranal Coulomat Ag Honeywell

Request Callback

₹ 9500 / Bottle Get Latest Price

Product Brochure
Formulation TypeLiquid anolyte solution for coulometric Karl Fischer titration.
BrandHoneywell
Purity99 %
Density0.93 g/cm3
Boiling Point63 degree c
Solution TypeKarl Fischer
GradeLaboratory Reagent (LR), Coulometric Karl Fischer (KF) Reagents
Form TypeLiquid
ColorLight yellow
Shelf Life5 Years
Flashpoint14 °C
Solubility in WaterCompletely miscible
Product Code34836
pH~5.0–6.0 (20°C)
AppearanceClear / Light yellow

Minimum order quantity: 1 Bottle

Honeywell 34836 is HYDRANAL Coulomat AG, a crucial reagent (anolyte) for coulometric Karl Fischer (KF) titration, used in laboratories to accurately determine trace moisture in samples like oils, pharmaceuticals, and solvents, known for its high accuracy, stability, and compatibility with both diaphragm and diaphragm-free cells, featuring methanol, SO₂, imidazole, and diethanolamine. Key Characteristics & Use:
  • Purpose: Anolyte reagent for Karl Fischer Coulometric Titration (moisture determination).
  • Applications: Oil & Gas, Pharma, Industrial Solvents, General Lab Use.
  • Composition: Contains Methanol, Sulfur Dioxide, Imidazole, Diethanolamine (pyridine-free).
  • Cell Compatibility: Works in KF cells with or without a diaphragm.
  • Appearance: Light yellow liquid.
  • Grade: Laboratory Reagent (LR).
  • Packaging: Available in 500ml and 1L bottles. 
Why it's Used:
  • High Accuracy: Excellent for trace water content.
  • Ease of Use: Simple to handle in titration setups.
  • Long Shelf Life: Stable for up to five years. 
In short, it's a high-quality, reliable chemical for precise water content analysis in various complex samples, especially when dealing with very low moisture levels. 

Honeywell Hydranal Coulomat A

Request Callback

₹ 11500 / Bottle Get Latest Price

Product Brochure
Formulation TypeLiquid reagent mixture
BrandHoneywell
Purity99 %
Cas Number68007-08-9
Density0.93 g/cm3
Boiling Point63 degree c
Solution TypeKarl Fischer
Product Code34807
Pack Size500ml
Shelf Life5 years
FlammableHighly flammable liquid and vapor (H225).
CompositionA mixture primarily of methanol, chloroform, sulfur dioxide, and diethanolamine (specif
ToxicToxic if swallowed, inhaled, or in contact with skin (H301, H311, H331).
Form TypeLiquid reagent
ColorTan/light color
Flash Point~11°C
pH (approx.)~6
SolubilityMiscible in water
HSN Code3821 00 00
Physical stateLiquid

Minimum order quantity: 1 Bottle

Honeywell HYDRANAL Coulomat A is a specific, high-quality anolyte reagent used for coulometric Karl Fischer titration to precisely measure trace water in samples, especially effective in cells with diaphragms, known for its reliability, stability, and part of a broader line of KF reagents offering accuracy for water content analysis in various samples like oils and non-polar substances, featuring methanol/chloroform base for optimal performance. Key Features & Use:
  • Application: Coulometric Karl Fischer (KF) Titration for determining trace water content.
  • Type: Anolyte solution for the anodic compartment in KF titration cells.
  • Composition: Contains iodide, an imidazole buffer, and sulfur dioxide in a suitable solvent, often methanol-chloroform based.
  • Cell Compatibility: Preferred for use in KF cells that have a diaphragm (separating anode/cathode) for highest accuracy, but also suitable for cells without diaphragms.
  • Benefits: High accuracy for trace water, stable titration conditions, long shelf life, and consistent quality.
  • Product Line: Part of Honeywell's comprehensive HYDRANAL™ brand, a leader in KF reagents. 
In Simple Terms:
Think of it as a specialized chemical "detector" for water. When used in a Karl Fischer titrator, Coulomat A provides the necessary chemicals to react with and quantify minute amounts of water in a sample, ensuring precise results for laboratory analysis. 

Hydranal Coulomat A Honeywell

Request Callback

₹ 12500 / Bottle Get Latest Price

Product Brochure
Formulation TypeLiquid formulated reagent
BrandHoneywell
Purity99 %
Cas Number68007-08-9
Boiling Point63 degree c
Solution TypeKarl Fischer
Product code34807
Pack Size500ml

Minimum order quantity: 1 Bottle

Honeywell HYDRANAL Coulomat A is a specific, high-quality anolyte reagent used for coulometric Karl Fischer titration to precisely measure trace water in samples, especially effective in cells with diaphragms, known for its reliability, stability, and part of a broader line of KF reagents offering accuracy for water content analysis in various samples like oils and non-polar substances, featuring methanol/chloroform base for optimal performance. Key Features & Use:
  • Application: Coulometric Karl Fischer (KF) Titration for determining trace water content.
  • Type: Anolyte solution for the anodic compartment in KF titration cells.
  • Composition: Contains iodide, an imidazole buffer, and sulfur dioxide in a suitable solvent, often methanol-chloroform based.
  • Cell Compatibility: Preferred for use in KF cells that have a diaphragm (separating anode/cathode) for highest accuracy, but also suitable for cells without diaphragms.
  • Benefits: High accuracy for trace water, stable titration conditions, long shelf life, and consistent quality.
  • Product Line: Part of Honeywell's comprehensive HYDRANAL™ brand, a leader in KF reagents. 
In Simple Terms:
Think of it as a specialized chemical "detector" for water. When used in a Karl Fischer titrator, Coulomat A provides the necessary chemicals to react with and quantify minute amounts of water in a sample, ensuring precise results for laboratory analysis. 

Hydranal Composite 5 Honeywell

Request Callback

₹ 25000 / Bottle Get Latest Price

Product Brochure
Packaging Size1 L
GradeAR (Analytical)
BrandHoneywell
Physical StateLiquid
Usage / ApplicationLaboratory
Packaging TypeGlass Bottle
ColorBrown
Country of OriginIndia
Shelf Life36 Months
suitability (for KF-titration)test passed
titer (water equivalent)4.5 - 5.5 mg/ml
Boiling Point/Range194 °C (1.013 hPa)
Density1.17 g/cm3 (25 °C)
Flashpoint99 °C
Incompatible MaterialsStrong oxidizing agents
pH-Value4.5-5.5 (20 °C)
Product LineHydranal™
Storage TemperatureAmbient
Product Code34805

Minimum order quantity: 1 Bottle

Honeywell Fluka Hydranal Composite 5 is a high-grade, single-component reagent used for volumetric Karl Fischer titration, typically featuring an Analytical Reagent (AR) grade for precise water determination. It acts as a titrant with a water equivalent of 4.5–5.5 mg/mL4.5 – 5.5 mg/mL4.5–5.5 mg/mL and is designed for stability and accuracy, often used for, but not limited to, analysis of aldehydes and ketones. Key Details for Hydranal Composite 5: 
  • Grade: Analytical Reagent (AR).
  • Purpose: Volumetric one-component Karl Fischer (KF) titration.
  • Water Equivalent (Titer): 4.5–5.5 mg/mL4.5 – 5.5 mg/mL4.5–5.5 mg/mL.
  • Components: Contains iodine, sulfur dioxide, and bases like imidazole dissolved in diethylene glycol monoethyl ether (DEGEE).
  • Shelf Life: Generally 3 years.
  • Advantages: Suitable for methanol-sensitive compounds (specifically K-type), improved stability, and reduced toxicity compared to methanol-based systems. Grade & Application Highlights:
    • Applications: Ideal for laboratory water content analysis in various substances.
    • Form: Liquid reagent.
    • Compatibility: Works well with Honeywell Hydra-nal™ solvent products. 

Honeywell Hydranal Coulomat Cg

Request Callback

₹ 14500 / Bottle Get Latest Price

Product Brochure
Packaging Size50ML
GradeAR (Analytical)
BrandHoneywell
Purity99.9 %
Physical StateBox
Usage / ApplicationLaboratory, Microbiology, Educational, Pharmaceutical, Analytical / QC
Packaging TypeBox
Country of OriginUK
Shelf Life60 Months
ColourLight Yellow
Product Code34840
Flash Point14°C (57.2°F).
AppearanceLight yellow liquid.
Density Range1.064 g/cm³ at 20 °C.
StorageAmbient temperature
Product FormLiquid

Minimum order quantity: 1 Bottle

HYDRANAL Coulomat CG is a methanol-based catholyte solution used in coulometric Karl Fischer titration, a method for determining water content in samples. It's a trusted brand known for quality and consistency, with a wide range of products and support resources available. Key aspects of HYDRANAL Coulomat CG:
  • Purpose:Used as a catholyte in coulometric Karl Fischer titrations to measure water content.
  • Composition:Methanol-based.
  • Features:
    • Pyridine-free and ethanol-based.
    • Known for quality, consistency, and innovation.
    • Part of a comprehensive Hydranal product portfolio.
    • Offers dedicated technical support and numerous application notes.
  • Safety:Harmful, flammable, and poses health hazards. Requires protective gear and careful handling.
  • Properties:
    • Color: Light yellow.
    • Density: 1.064 g/cm3 at 20°C.
    • Flash point: 14°C.
    • Incompatible with oxidizing agents. 

Hydranal Coulomat AK Honeywell

Request Callback

₹ 29000 / Bottle Get Latest Price

Packaging Size500 ml
GradeAR Grade
BrandHoneywell
Technique SuitabilityCoulometric Titration
Physical FormLiquid
ApplicationLaboratory
Packaging TypeGlass Bottle
Packaging DetailsBottle of 500 ml
Usage/ApplicationLaboratory
Country of OriginMade in India
ColorYellow
FormLiquid
Storage TemperatureAmbient
Product Code34820
Product LineHydranal
PH-Value20 C

Minimum order quantity: 1 Bottle

Honeywell HYDRANAL-Coulomat AK is a reagent used for coulometric Karl Fischer titration, specifically in ketone-based samples where a methanol-free solution is preferred, according to Honeywell Research Chemicals. It's designed for use in cells with a diaphragm. The reagent can develop trace amounts of iodine during storage, indicated by a brown color, which can be removed by exposure to humid air before use. Here's a more detailed breakdown:
  • Coulometric Karl Fischer Titration:This method is used to determine the water content in various samples, including those containing ketones. 
  • Anolyte:HYDRANAL-Coulomat AK is an anolyte, meaning it's the solution used in the anodic (positive) compartment of the titration cell. 
  • Ketone Compatibility:It's specifically designed to be used in samples containing ketones, where a methanol-free solution is preferred to avoid potential side reactions. 
  • Diaphragm Cells:It's designed for use in titration cells that include a diaphragm, a physical barrier separating the anodic and cathodic compartments. 
  • Iodine Formation:During storage, the reagent can form trace amounts of free iodine, which is indicated by a light brown color. 
  • Iodine Reduction:This iodine can be removed by exposing the opened bottle to humid air before use. 
  • Suitability Test:A suitability test is often performed to ensure the reagent is appropriate for the specific Karl Fischer titration being conducted. 

Nitric Acid 2.5L Honeywell

Request Callback

₹ 16500 / Piece Get Latest Price

Packaging Size2.5l
BrandHONEYWELL
Packaging DetailsPlastic Bottle
Usage/ApplicationLaboratory/ R&D
ColorLight Yellow
Country of OriginMade in India
GradeTrace Analysis
Boiling Point122 C
Density1.420 G
FormLiquid
Melting Point-38 C
Purity Percentage69%
Product LineTrace Seles

Minimum order quantity: 1 Piece

  • Nitric acid, specifically Honeywell's 2.5L product, is a highly corrosive and oxidizing acid with the chemical formula HNO3. It is a strong acid, typically colorless, but may turn yellowish or reddish due to decomposition. The Honeywell product is available in a semiconductor grade (VLSI) and is known for its purity and use in various industrial and laboratory applications. Key Characteristics and Properties:
    • Chemical Formula: HNO3.
    • Appearance: Colorless to yellowish liquid.
    • Odor: Pungent, acrid smell.
    • Purity: Honeywell offers various grades, including Semiconductor grade (VLSI) with a purity of 69-71%.
    • Density: Approximately 1.51 g/cm³.
    • Boiling Point: 83°C.
    • Melting Point: -42°C.
    • Solubility: Highly soluble in water.
    • Corrosivity: Highly corrosive to metals and tissue.
    • Oxidizing Agent: Powerful oxidizing agent, reacting with many materials.
    • Toxicity: Toxic by inhalation and can cause severe burns. 
    Common Uses:
    • Semiconductor Manufacturing:Honeywell's semiconductor grade nitric acid is used for etching and cleaning processes in the semiconductor industry. 
    • Laboratory Reagent:It's a common reagent in chemical laboratories for various reactions and analyses. 
    • Metal Cleaning and Etching:Nitric acid is used to clean and etch metals in various industrial processes. 
    • Production of Fertilizers and Explosives:It's a key ingredient in the production of ammonium nitrate for fertilizers and nitroglycerin and TNT for explosives. 
    • Cleaning-in-place (CIP):Used in cleaning processes for removing mineral scale and preventing precipitation in various systems. 
    • Purification of Noble Metals:Nitric acid can be used to purify noble metals like platinum, gold, and silver. 
    • Aqua Regia Production:It forms aqua regia when combined with hydrochloric acid, which can dissolve even gold and platinum. 

Hydrochloric Acid Honeywell

Request Callback

₹ 19470 / Kg Get Latest Price

Packaging Size1 L
GradeAR (Analytical)
BrandHoneywell
Packaging DetailsPlastic Bottle
Physical FormLiquid
ApplicationLaboratory
Packaging TypePlastic Bottle
Usage/ApplicationLaboratory
ColorWhite
Country of OriginMade in India
Shelf Life12 Months
Physical StateLiquid
Storage InstructionsRoom temperature
Supply Ability10 Per Day
Weight1.20 Gram
Pack Size1L
Product Code08256

Minimum order quantity: 1 Kg

Honeywell's Hydrochloric Acid (HCl) is a highly corrosive, colorless liquid, also known as muriatic acid or spirits of salt. It's an aqueous solution of hydrogen chloride and is completely miscible in water. Honeywell offers various grades of HCl, including ACS Grade and Reagent Grade, with assays typically ranging from 36.5% to 38.0%. It's used in a wide range of applications, including chemical synthesis, metal cleaning, and laboratory analysis. Key Characteristics:
  • Chemical Formula: HCl
  • Molar Mass: 36.46 g/mol
  • Physical State: Liquid (aqueous solution)
  • Appearance: Colorless
  • Corrosivity: Corrosive to metals
  • Boiling Point: Approximately 42 °C (1.013 hPa)
  • pH: >0.1 (20 °C)
  • Density: 1.190 g/cm³ (20 °C)
  • Solubility: Completely miscible in water
  • Storage Temperature: Ambient 
  • Uses:
    • Chemical synthesis
    • Metal cleaning and pickling
    • Oil well stimulation (acidizing)
    • Laboratory analysis
    • Production of chlorides, fertilizers, and dyes
    • Electroplating
    • Photography
    • Textile and rubber industries 
    Important Notes:
    • Hydrochloric acid is highly corrosive and can cause severe burns to skin, eyes, and mucous membranes. 
    • Proper safety precautions, including personal protective equipment (gloves, eye protection, and appropriate clothing), should be used when handling hydrochloric acid. 
    • It should be stored away from incompatible materials such as metals, water, amines, acetic anhydride, ethyleneimine, ammonia, chlorosulfonic acid, sulfuric acid, strong bases, alkalis, and strong oxidizing agents. 

HYDRANAL Coulomat AD Honeywell

Request Callback

₹ 18500 / Bottle Get Latest Price

Formulation TypeKarl Fischer Solvent
Packaging Size500 ml
GradeCoulometric KF Reagents
BrandHoneywell
Purity>99.9%
Chemical FormulaCH₃OH
Physical FormLiquid
Physical StateLiquid
Cas Number67-56-1
Usage / ApplicationLaboratory
ApplicationLaboratory
Molecular Weight32.04 g/mol
Packaging TypeGlass Bottle
Country of OriginIndia
Storage TemperatureAmbient
Product Code34810
CompositionMethanol, imidazole, sulfur dioxide, diethanolamine
Density0.930 g/cm3 (20 °C)
suitability (for KF-titration)test passed
Boiling Point/Range63 °C (1.013 hPa)
Color TypeLight Yellow
Flashpoint26.5 %(V)
For Use With (Equipment)KF Titration
Incompatible MaterialsOxidizing agents
Lower Explosion Limit5.5 %(V)
Upper Explosion Limit26.5 %(V)
Vapor Pressure128 hPa (20 °C)
Product LineHydranal™

Minimum order quantity: 1 Bottle

The Honeywell 34810 refers to HYDRANAL Coulomat AD, a chemical reagent used as the anolyte (the positive electrode solution) for coulometric Karl Fischer titration to determine water content, particularly for cells without a diaphragm. It's a methanol-based solution supplied by Honeywell under their Fluka brand and is available in various sizes, such as 500 mL and 6x500mL bottles, through scientific suppliers. Key Details:
  • Product: HYDRANAL™ - Coulomat AD.
  • Application: Coulometric Karl Fischer titration (anolyte).
  • Type: Methanol-based, for cells without a diaphragm.
  • Manufacturer: Honeywell (Fluka brand).
  • Common Sizes: 500 mL (34810-500ML) or 6x500mL (34810-6X500ML). The product number 34810 refers to HYDRANAL™-Coulomat AD, which is an anolyte reagent solution used for coulometric Karl Fischer (KF) titration to determine water content in various substances. It is a product from Honeywell Specialty Chemicals, often sold under the Honeywell Fluka™ brand. Key Specifications
    Property ValueSource
    Product Name HYDRANAL™-Coulomat AD
    Use Reagent for coulometric KF titration (anolyte solution)
    Preferred Use For cells without a diaphragm
    Form Liquid
    Color Light Yellow
    Quantity Typically 500 mL per bottle
    Composition Methanol, imidazole, sulfur dioxide, diethanolamine
    Suitability Test passed for KF titration
    Assay of water 5 - 50 ppm (parts per million)
    Physical and Safety Information
    • Boiling Point: 63 °C (145.4 °F)
    • Density: 0.930 g/cm³ at 20 °C
    • Flash Point: 11 °C (51.8 °F)
    • Solubility in Water: Completely miscible
    • Storage Temperature: Ambient temperature
    • Safety: Highly flammable liquid and vapor, toxic if swallowed, in contact with skin, or inhaled. Causes serious eye damage and may damage organs through prolonged or repeated exposure. Safety Data Sheets are available from suppliers like Fisher Scientific. 
    This reagent is a core part of the comprehensive Hydranal portfolio from Honeywell for accurate water determination in laboratory settings. 

Hydrochloric Acid Honeywell

Request Callback

₹ 7500 / Litre Get Latest Price

Packaging Size1 L
GradeTraceSELECT™, for trace analysis
Molecular Weight36.46 g/mol
BrandHoneywell
Physical StateLiquid
Usage / ApplicationLaboratory
Packaging TypePlastic Bottle
ColorColorless
Country of OriginIndia
Shelf Life12 Months
Density~1.19 g/cm³ (20 °C)
Boiling Point~42 °C
CAS Number7647-01-0
CorrosivityHighly corrosive to metals and other materials.
SolubilityCompletely miscible in water.
Chemical FormulaHCl.
AppearanceColorless liquid.
OdorStrong, pungent, and irritating.
Assay (Purity)≥ 30% w/w hydrochloric acid (HCl) solution
SynonymsMuriatic acid, chlorhydric acid, spirits of salt
Molar Mass36.46 g/mol
Molecular FormulaHCl
Melting Point.Approx –35 °C
Product Code08256
pH (20 °C)Highly acidic, typically < 1
Viscosity~1.9 mPa·s at 15 °C
Storage ConditionsAmbient; keep tightly closed and protected from contaminants
Incompatible MaterialsStrong bases/alkalis, oxidizing agents, metals, amines, etc
Purity (Assay)Greater than or equal to 30% (≥30%)
HSN Code28061000

Minimum order quantity: 1 Litre

Honeywell's hydrochloric acid (Salzsäure in German) is an aqueous solution of hydrogen chloride (HCl) offered in various purity grades for laboratory and industrial use. It is a strong, corrosive mineral acid with a pungent odor. Key Characteristics of Honeywell HCl
  • Appearance: Colorless liquid.
  • Odor: Strong, pungent, and irritating.
  • Corrosivity: Highly corrosive to metals and other materials.
  • Solubility: Completely miscible in water.
  • Chemical Formula: HCl.
  • Molar Mass: 36.46 g/mol.
  • Typical Concentration (Assay): Varies by grade, with common concentrations around 36.5-38.0% for concentrated grades. Honeywell also offers specific volumetric solutions (e.g., 0.1 M, 1 M, 6 M). 
Available Grades and ApplicationsHoneywell (often through its Fluka brand) provides several grades to meet different application requirements: 
  • ACS Reagent Grade: Meets American Chemical Society (ACS) standards for purity, suitable for general laboratory analysis.
  • Reagent Grade / Analytical Grade (AR): Used for general lab purposes and chemical synthesis.
  • Semiconductor Grade / TraceSELECT™: Extremely high purity with very low trace metal content (parts per billion or trillion levels), specifically for use in the semiconductor industry.
  • Volumetric Solutions: Pre-made standard solutions with precise concentrations (e.g., 1 M, 0.1 M), often traceable to NIST standards, for titration and quantitative analysis. 

Honeywell Hexane 2.5ltr

Request Callback

₹ 7500 / Gram Get Latest Price

Packaging Size2.5 L
GradeLC-MS CHROMASOLV™
BrandHoneywell
Physical FormLiquid
Physical StateLiquid
ApplicationLaboratory
Usage / ApplicationLaboratory
Packaging TypeGlass Bottle
Purity>97%
ColorColorless
Country of OriginIndia
Shelf Life24 Months
Assay (GCMinimum 97%
Water Content (Karl Fischer)Maximum 0.01%
Boiling Point/Range66 - 69 °C
AppearanceColorless liquid
Product Code34986
Vapor Pressure160 hPa at 20 °C
Flashpoint7.4% (V)
Density0.660 - 0.668 g/cm³ at 20 °C
Formula Weight86.18 g/mol
CAS Number110-54-3
StorageAmbient temperature.

Minimum order quantity: 1 Gram

Honeywell Riedel-de Haën™ 34986 is a Hexane CHROMASOLV™ LC-MS grade solvent, designed for high-purity applications. It is a colorless liquid optimized for liquid chromatography-mass spectrometry (LC-MS) and other demanding analytical techniques, offering high purity (typically $\ge$97%) and low impurity levels. Solstice Research Chemicals +2Key Specifications & Features
  • Grade: LC-MS CHROMASOLV™
  • Assay (GC): Minimum 97%
  • Water Content (Karl Fischer): Maximum 0.01%
  • Application: Suitable for LC-MS, HPLC, and UV-spectroscopy
  • Boiling Point/Range: 66 - 69 °C
  • Appearance: Colorless liquid
  • Non-volatile Matter: Max 0.0005% Solstice Research Chemicals +3
ApplicationsThe 34986 Hexane solvent is primarily used in industries requiring high-purity solvents, including:
  • Analytical Chemistry: LC-MS and HPLC-MS analysis
  • Pharmaceutical: API purity quantitation and solid-phase extraction (SPE)
  • Environmental: Pesticide residue analysis 

Hydranal Titrant 5 Honerwell

Request Callback

₹ 14000 / Bottle Get Latest Price

Packaging Size500 ml
GradeLab
BrandHoneywell
Physical FormLiquid
ApplicationLaboratory
Packaging TypeGlass Bottle
Country of OriginIndia
Shelf Life36 Months
Product Number34801
Product TypeVolumetric two-component reagent
Storage3-year shelf life under appropriate conditions
Density0.85g/mL
Flash Point11°C (51.8°F)
ColourBrown
SolubilityCompletely miscible in water
Storage TemperatureAmbient (15–25°C)

Minimum order quantity: 1 Bottle

Honeywell 34801 HYDRANAL™-Titrant 5 is a methanol-based, two-component reagent designed for volumetric Karl Fischer titration, offering a titer of ~5 mg/mL of water. It provides high titration speed, stability, and accuracy. It is typically used with a working medium solvent, such as HYDRANAL-Solvent. Honeywell +2Key Features and Specifications
  • Product Name: HYDRANAL™-Titrant 5
  • Product Number: 34801
  • Type: Volumetric two-component reagent

Hydranal Solvent CM Honeywell

Request Callback

₹ 18000 / Litre Get Latest Price

Packaging Size1 L
GradeAR (Analytical)
BrandHoneywell
Physical FormLiquid
ApplicationLaboratory
Packaging TypeGlass Bottle
ColorColorless
Country of OriginIndia
Shelf Life36 Months
Product Number34812
CompositionChloroform-methanol-based.
Cas Number67-66-3
Boiling Point60°C to 65°C
Density1.26 g/mL
HSN Code38220090
SolubilityMiscible with organic solvents
AppearanceClear, colorless liquid

Minimum order quantity: 1 Litre

Based on your search, "34812" refers to HYDRANAL™ Solvent CM, a specialized chemical reagent produced by Honeywell Research Chemicals, not a share ticker.HYDRANAL™ Solvent CM Specifications (34812)
  • Product Name: HYDRANAL-Solvent CM
  • Product Number: 34812-1L (1 Liter)
  • Description: Medium for volumetric two-component Karl Fischer titration.
  • Composition: Chloroform-methanol-based.
  • Application: Ideal for titration in non-polar substances, such as fats and oils.

HYDRANAL Water Standard Oil Honeywell

Request Callback

₹ 18500 / Piece Get Latest Price

Product Brochure
Packaging DetailsBox
Usage/ApplicationLaboratory/R & D Purposes
ColorColorless
BrandHoneywell Fluka
Country of OriginMade in India
Density15 C 0.98 g/cm3
Nominal water content0.1 mg/g H2O
Volume0.08 L (80 mL)
MatrixOil-based non-polar
Pack Size80ml(10x8)
Melting Point/Range-15 DegreeC

Minimum order quantity: 1 Piece

Honeywell's HYDRANAL™ Water Standard Oil is an oil-based solution containing approximately 10 ppm of water, used as a standard for Karl Fischer titration to calibrate and validate water content measurement instruments. This liquid standard provides a stable and precisely determined water content, making it easier to handle and more accurate than pure water for quality control. It is packaged in ampoules for convenience and is traceable to external standards, such as the NIST SRM 2890 standard reference material. Key Characteristics:
  • Application: Standard for Karl Fischer titration to determine water content. 
  • Water Content: Contains a precise amount of water, with the exact value listed on the report of analysis (e.g., ~10 ppm). 
  • Format: Liquid standard, available in glass ampoules. 
  • Packaging: Sold in boxes containing multiple single-use, pre-notched ampoules for ease of opening. 
  • Quality: Verified against external standards, such as NIST SRM 2890. 
  • Purpose: Used for calibrating, validating, and performing quality control of analytical instruments and reagents in Karl Fischer titration. 
Why Use a Water Standard Oil? 
  • Handling: Easier and more accurate to handle than pure water for low-concentration water content measurements.
  • Stability: Provides a stable and reliable source of water for consistent results.
  • Traceability: Ensures results can be traced to national standards, which is often required in quality guidelines.

Hydranal Water Standard 0.1 Honeywell

Request Callback

₹ 9151 / Piece Get Latest Price

Product Brochure
Standard TypeWater Standard
Packaging Size40ML
Temperature Range2°C – 8°C
BrandHoneyWell
Packaging DetailsGlass Bottle
Melting Point25 °C (approx.)
GradeExtra pure
Usage/ApplicationLaboratory/R&D
ColorWhite
Country of OriginMade in India
Product Code34847
Pack Size40ML

Minimum order quantity: 1 Piece

HYDRANAL Water Standards are liquid solutions with precisely known water content, used for calibrating and validating Karl Fischer titrators. They are packaged in easy-to-open ampoules and tested against NIST reference materials. These standards are used for titer determination, ensuring accuracy and precision in water content analysis. Key Features of HYDRANAL Water Standards:
  • Purpose: Calibrating and validating Karl Fischer titrators, ensuring accuracy and precision in water content analysis. 
  • Form: Liquid solutions with a specific water content. 
  • Packaging: Individual ampoules (often 10 per pack) for single use, under an argon atmosphere. 
  • Testing and Calibration: Tested against national metrological standards (e.g., NIST SRM 2890) and calibrated based on high-purity water or traceable to SI units. 
  • Shelf Life: Long shelf life, often up to five years. 
  • Applications: Titer determination, monitoring precision and accuracy, validation and inspection of Karl Fischer titrators, and volumetric/coulometric Karl Fischer applications. 
  • Versatility: Available in various water content levels (e.g., 0.1 mg/g, 1 mg/g, 10 mg/g). 
  • Example: Honeywell Research Chemicals offers a 0.1 mg/g standard. 

HYDRANAL Water Standard 1.0 Honeywell

Request Callback

₹ 15000 / Bottle Get Latest Price

Product Brochure
Standard TypeWater Standard
Packaging Size40ML
Temperature Range15-25 °C
BrandHoneywell
Melting Point37 °C
CAS Number34840
GradeLaboratory Reagent Grade (LR)
Packaging Details50ml
Appearance (colour)Light Yellow
Usage/ApplicationLaboratory
Density1.064 g/cm3 (20 DegreeC)
Boiling Point (BP)63 DegreeC (1.013 hPa)

Minimum order quantity: 1 Bottle

Hydranal Coulomat CG, manufactured by Honeywell, is a methanol-based catholyte solution used in Karl Fischer coulometric titration for determining water content. It's a trusted reagent known for its quality and consistency in laboratory settings. Key features and properties:
  • Purpose: Specifically designed for Karl Fischer coulometric titration, a technique for accurately measuring trace amounts of water. 
  • Composition: The reagent is a catholyte solution based on methanol. 
  • Application: Suitable for use in cells with or without a diaphragm. 
  • Quality: A pyridine-free and ethanol-based reagent, known for its reliability and long shelf life (up to five years). 
  • Safety: Harmful, flammable, and poses potential health hazards. Proper precautions, including wearing protective gear and avoiding ingestion, are essential. 
  • Technical Support: Honeywell offers dedicated technical support and application notes for Hydranal reagents. 
In essence, Hydranal Coulomat CG is a critical component in the precise measurement of water content, particularly in laboratory settings, utilizing the Karl Fischer titration method. 
X

Contact Us

Mukesh Patel (CEO)
AM Scientific
2nd Floor, B-19, Kanha Residency, Bhaskar Enclave 2, Golyawas, Mansarovar
Jaipur - 302020, Rajasthan, India

Get Directions
Send Email
Share: